Panel Air Cylinders Dia 6-10-16 - 429 Type E |
FEATURES • Compact cylinders with rear connection(s), including double acting cylinder. • Its threaded body and nuts afford - Easy adaptation on any support through its tapped or smooth hole - Adjustable body axis opposite the support. |
Data Sheet 429 E pdf
|
|
|
|
Micro-Cylinders Dia 2.5-4 and 6mm - 435 |
GENERAL - Fluid Air or neutral gas, filtered at 5μm, lubricated or not - Operating pressure min. 3.5 (3 bar for Ø 6 mm) max. 8 bar - Ambient temperature + 5°C to + 60°C |
Data Sheet 435 pdf
|
|
|
|
Short-Stroke Air Cylnders Dia 8 to 100mm - 441 K |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 2 to 10 bar Ambient temperature - -10°C to +70°C |
Data Sheet 441 K pdf
|
|
|
|
Short-Stroke Air Cylinder Dia 8 to 100mm -Double Crossbar Type - 441 K |
GENERAL AND CONSTRUCTION identical to the standard double acting version |
Data Sheet 441 K pdf
|
|
|
|
Short-Stroke Air Cyinders Dia 20 to 100mm - With Antirotation Device - 441 K |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 2 to 10 bar Ambient temperature - -10°C to +70°C |
Data Sheet 441 K pdf
|
|
|
|
Joucomatic 442 KN L DM With A Rotation-Proof Device On The Bearing-Rod - 442 KN L DM |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 10 bar max. Ambient temperature - -20°C to +70°C Max. speed 0,5 m/s Standards - AFNOR NF E 49-004-2 |
Data Sheet 442 KN L DM pdf
|
|
|
|
Short-Stroke Air Cylinder Dia 20 to 25mm - 442 KN-DM KN-T2-DM |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 2 to 10 bar max. Ambient temperature - -20°C to +70°C Max. speed 0,5 m/s Standards - AFNOR NF E 49-004 |
Data Sheet 442 KN-DM KN-T2-DM pdf
|
|
|
|
Joucomatic Air Cylinder Isoclair Dia 8 to 25mm - C ASDM |
FEATURES • Good resistance to corrosive elements (barrel and stainless steel rod) GENERAL Detection - Equipped or not for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 2 to 10 bar Ambient temperature - 0°C to +70°C (Ø8-10) / -10°C to +70°C (Ø12 to 25) Standards - ISO 6432 - 8140 - 8139 CETOP - RP 52 P - RP 102 P - RP 103 P AFNOR - NF E 49-030 |
Data Sheet C ASDM pdf
|
|
|
|
Joucomatic Air Cylinders Isoclair Dia 8 to 25mm Non ISOCETOPAFNOR Standardised - CC AS |
FEATURES • Good resistance to corrosive elements (barrel and stainless steel rod) GENERAL Detection - Equipped or not for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 2 to 10 bar Ambient temperature - -10°C to +70°C Standards - ISO 6432 - 8139 - 8140 CETOP - RP 52 P - RP 102 P - RP 103 P AFNOR - NF E 49-030 - NF E 49-035 - NF E 49-036 |
Data Sheet CC AS pdf
|
|
|
|
Joucomatic Air Cylinder Isoclair Dia 32 to 63mm-ISOTOP - CIS NADM |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 10 bar max. Ambient temperature - - 10°C to + 70°C Standards - ISO 6431 - 8139 - 8140 CETOP - RP 43 P - RP 102 P - RP 103 P |
Data Sheet CIS NADM pdf
|
|
|
|
Joucomatic Anti-corrosive Cylinders Isoclair Dia. 12 to 25mm-ISO CETOP - CIX |
FEATURES These cylinders are designed for use in corrosive environments: • chemical, salty or humid atmospheres • food processing industry (dairy and meat industries): high resistance to lactic acid and bactericidal sprays. |
Data Sheet CIX pdf
|
|
|
|
Joucomatic Anti-corrosive Cylinders Dia. 32 to 80 mm-ISO CETOP - CIX |
FEATURES The cylinders are designed for use in corrosive environments: • chemical, salty and humid atmospheres • food processing industry (dairy and meat industries): high resistance to lactic acid and bactericidal sprays |
Data Sheet CIX pdf
|
|
|
|
Short-Stroke Air Cylinder Dia. 20 - 25mm-AFNOR NFE 49-004-With Antirotation Device - KL DM |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 10 bar max. Ambient temperature - -20°C to +70°C Max. speed 0,5 m/s Standards - AFNOR NF E 49-004-2 |
Data Sheet KL DM pdf
|
|
|
|
Short-Stroke Air Cylnders Dia. 20 - 25mm - AFNOR NFE 49-004 - KN DM |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 2 to 10 bar max. Ambient temperature - -20°C to +70°C Max. speed 0,5 m/s Standards - AFNOR NF E 49-004 |
Data Sheet KN DM pdf
|
|
|
|
Micro 10 Air Cylinders Dia. 2.5 - 6mm - 435 |
GENERAL Fluid - Air or neutral gas, fi ltered at 5μm, lubricated or not Operating pressure - min. 3.5 (3 bar for Ø 6 mm) max. 8 bar Ambient temperature + 5°C to + 60°C |
Data Sheet 435 pdf
|
|
|
|
Joucomatic CNOMO Cylinders Dia. 25 - 200mm - PCN |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gas fi ltered, lubricated or unlubricated Operating pressure - Max. 10 bar Ambient temperature - - 10°C to + 70°C Standards - CNOMO 06-07-02 to 06-07-15 AFNOR - NFE 49001 - NFE 49002 NFE - 49011 to NFE 49015 |
Data Sheet PCN pdf
|
|
|
|
Joucomatic Compact Cylinders Dia. 32 - 100mm Compatible With ISO15552AFNORDIN-Single And Double Acting - PEC DM |
SPECIFICATIONS DETECTION : Equipped for magnetic position detectors FLUID : air or neutral gas, filtered, lubricated or not PRESSURE : 2 to 10 bar max. TEMPERATURE :-20°C, +70°C CYLINDER BORE : 32 to 100 mm STROKE : 5 to 25 mm MAX. SPEED : 0,5 m/s STANDARD : The diameters and distances between the centres of the mounting holes ensures that any fittings can be attached that comply with ISO 15552-AFNOR NF ISO 15552-DIN ISO 15552 (replace ISO 6431 - AFNOR NFE 49003 - VDMA 24562) |
Data Sheet PEC DM pdf
|
|
|
|
Joucomatic Compact Cylinders Dia. 32 - 100mm Compatible With ISO15552AFNORDIN-Hollow Through Rod Type - PEC DM |
APPLICATION The hollow through rod version enables compact installation of the vacuum pick-up system. It facilitates: ● direct attachment of the suction cup to the end of the rod on the working side, ● direct connection of the vacuum line to the other side. A wide range of available connection sizes ensures that any type or size of suction cup can easily be fitted (see table opposite). |
Data Sheet PEC DM pdf
|
|
|
|
Joucomatic Compact Cylinders Dia. 32 - 100mm Compatible With ISO15552AFNORDIN-With Supplies On The Same Extremity - PEC FE DM PEC RE DM |
SPECIFICATIONS DETECTION : Equipped for magnetic position detectors FLUID : Air or neutral gas, filtered, lubricated or not PRESSURE : 10 bar max. TEMPERATURE : -20°C, +70°C CYLINDER BORE : 32 to 100 mm MAX. STROKE : 400 mm STANDARD : The diameters and distances between the centres of the mounting holes ensures that any fittings can be attached that comply with ISO 15552-AFNOR NF ISO 15552-DIN ISO 15552 (replace ISO 6431 - AFNOR NFE 49003 - VDMA 24562) |
Data Sheet PEC FE DM PEC RE DM pdf
|
|
|
|
Joucomatic Compact Cylinders Dia. 32 - 100mm Compatible With ISO15552AFNORDIN-With Antirotation Device - PEC L DM |
SPECIFICATIONS DETECTION : Equipped for magnetic position detectors FLUID : air or neutral gas, filtered, lubricated or not PRESSURE : 2 to 10 bar max. TEMPERATURE :-20°C, +70°C CYLINDER BORE : 32 to 100 mm STROKE : 5 to 25 mm MAX. SPEED : 0,5 m/s STANDARD : The diameters and distances between the centres of the mounting holes ensures that any fittings can be attached that comply with ISO 15552-AFNOR NF ISO 15552-DIN ISO 15552 (replace ISO 6431 - AFNOR NFE 49003 - VDMA 24562) |
Data Sheet PEC L DM pdf
|
|
|
|
Joucomatic ISO 15552 Cylinders Dia. 32 - 200mm With Tie Rods - PES 450 |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 10 bar max. Ambient temperature - –20°C, to +70°C (for higher t°, see page P239) Optimal max. speed ≤ 1 m/s (for optimal service life) Max. speed rate 2 m/s Standards ISO 15552-AFNOR NF ISO 15552-DIN ISO 15552 (replace ISO 6431-AFNOR NFE 49003-VDMA 24562) |
Data Sheet PES 450 pdf
|
|
|
|
Joucomatic ISO 15552 Cylinders Omega Dia. 32 - 80mm-With Profiled Barrel - PES 450 |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 10 bar max. Ambient temperature - –25°C to +80°C (without position detectors) (for higher temperatures, consult us) –20°C to +70°C (with position detectors) Optimal max. speed ≤ 1 m/s (for optimal service life) Max. speed rate 3 m/s (at 20°C) Standards - ISO 15552-AFNOR NF ISO 15552-DIN ISO 15552 (replace ISO 6431-AFNOR NFE 49003-VDMA 24562) |
Data Sheet PES 450 pdf
|
|
|
|
Joucomatic ISO 15552 Cylinders Omega Dia. 32 - 80mm-With Tie Rods - PES 450 |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 10 bar max. Ambient temperature - –25°C to +80°C (without position detectors) (for higher temperatures, consult us) –20°C to +70°C (with position detectors) Optimal max. speed ≤ 1 m/s (for optimal service life) Max. speed rate 3 m/s (at 20°C) Standards - ISO 15552-AFNOR NF ISO 15552-DIN ISO 15552 (replace ISO 6431-AFNOR NFE 49003-VDMA 24562) |
Data Sheet PES 450 pdf
|
|
|
|
Joucomatic ISO 15552 Cylinders Dia. 32 - 125mm With Profiled Barrel For Flush-Mount Position Detectors-VDMAISO - PES P DM |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 10 bar max. Ambient temperature - –20°C to +70°C (for higher temperatures, consult us) Optimal max. speed ≤ 1 m/s (for optimal service life) Max. speed rate 2 m/s Standards - ISO 15552-AFNOR NF ISO 15552-DIN ISO 15552 (replace ISO 6431-AFNOR NFE 49003-VDMA 24562) |
Data Sheet PES P DM pdf
|
|
|
|
Joucomatic ISO 15552 Cylinders Dia. 32 - 200mm With Tie Rods-Through Rod Type - PES RDM T2 |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 10 bar max. Ambient temperature - –20°C, to +70°C Optimal max. speed ≤ 1 m/s (for optimal service life) Max. speed rate 2 m/s Standards ISO 15552-AFNOR NF ISO 15552-DIN ISO 15552 (replace ISO 6431-AFNOR NFE 49003-VDMA 24562) |
Data Sheet PES RDM T2 pdf
|
|
|
|
Joucomatic ISO 6431-CETOP Cylinders with Tie Rods-Dia. 250mm - PIS |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gaz fi ltered, lubricated or not Pressure - 10 bar max. Temperature - -10°C to +70°C Standards - ISO 6431 |
Data Sheet PIS pdf
|
|
|
|
Rotatable Cylinders 2,3 or 4 Positions Dia. 12 - 22mm - 429 Type R |
GENERAL Detection - Equipped for magnetic position detectors Fluid - Air or neutral gas, fi ltered, lubricated or not Operating pressure - 1 to 7 bar Ambient temperature - + 5°C, +60°C Rotation 90° - 180° ( ±5° ) Cushioning Non cushioned |
Data Sheet 429 Type R pdf
|
|
|
|
Rodless Band Cylinders Dia. 25 - 63mm - STBN STB |
SPECIFICATIONS FLUID : air or neutral gas, fi ltered, lubricated or NOT PRESSURE : 8 bar max TEMPERATURE : - 10°C, + 65°C STROKE min. : 100 mm (for detectors) max. standard : 3500 mm (Ø 25 mm) : 3400 mm (Ø 32 to 50 mm) : 3300 mm (Ø 63 mm) (consult us for longer strokes) MAXIMUM VELOCITY : 2 m/sec |
Data Sheet STBN STB pdf
|
|
|
|
Rodless Band Cylinders Dia. 16 - 80mm (STBN-STB) Dia. 25 - 50mm (STBB) - STBN STB STBB |
COMPACT INSTALLATIONS As this cylinder is rodless, installation space is cut by almost half compared to a standard cylinder with a rod. |
Data Sheet STBN STB STBB pdf
|
|
|
|
Rodless Cylinders, Magnetically Induced Dia. 6 - 40mm - STN STG |
Unlike the traditional pneumatic cylinders, the linear drive cylinders with magnetic coupling are rodless, with reduced dimensions, an easier sliding of the cylinder within the mechanism and a different positioning of the load to move. This type of cylinder is compact. |
Data Sheet STN STG pdf
|
|
|
|
Magnetic Detectors - 881 |
881 Detectors- Operation The permanent magnet is mounted in the piston head. On getting closer, its own magnetic field generates variations of the current within the detector oscillator. An amplifier converts them into switch signals. |
Data Sheet 881 pdf
|
|
|
|